SHENZHEN CREATIVE INDUSTRY CO., LTD.
|
Place of Origin: | Guangdong, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
The new generation of Lepu AI intelligent multi para patient monitor, which is divided into a 13.3-inch version V12 and an 11.6-inch version V10, with hardware ergonomic design and software flat interactive design, will meet the different needs in different departments of hospitals. It changes the working mode of the medical staff and brings them an unprecedented user experience.
Lepu Medical AiView V12 Multiparameter Patient Monitor Portable All-in-one Vital Signs Monitor Illustration
Features of Lepu Medical AiView V12 Multiparameter Patient Monitor Portable All-in-one Vital Signs Monitor
Highly accurate measurement of SpO2, pulse rate, ECG, NIBP (non-invasive blood pressure), body temperature, and respiration.
Optional functions: high-precision measurement of EtCO2, CSI (brain state index).
Supports use with Central Monitoring System (CMS).
HL7 protocol, Bed to bed view and 12-lead ECG available.
Support network interface, USB interface, VGA, serial port, analog output, and synchronous defibrillation.
Data export and software upgrade.
Technical Specification of Lepu Medical AiView V12 Multiparameter Patient Monitor Portable All-in-one Vital Signs Monitor
Technical Specification
ECG
Measurement range 15bpm~350bpm
Measurement accuracy ±1% or ±1 bpm, whichever is greater
Waveform sweeping speed 6.25mm/s, 12.5mm/s, 25mm/s, 50mm/s, error: ≤ ±5%
RESP
Measurement method Thoracic impedance
Respiration rate measurement range Adult: 0 rpm~120 rpm Pediatric and neonate: 0 rpm~150 rpm
Respiration rate measurement accuracy 7~120 rpm: ±2 rpm or ±2%, whichever is greater
0~6 rpm: not defined
TEMP
Measuring range 0°C~50°C (32°F~122°F)
Measuring accuracy Within the range of 1°C~50°C, the maximum allowable error is ±0.1°C
SPO2
Measurement range 0%~100%
Measurement accuracy 70%~100%: ±2
50%~69%: ±3%
0%~49%: not defined
PR measurement range 30bpm~250bpm
PR measurement accuracy ±2bpm or ±2%, whichever is greater
NIBP
Measurement method MANU, AUTO, STAT, Series
Measurement range 0 mmHg~300 mmHg (0.0 kPa~40.0 kPa)
Measurement accuracy ±3 mmHg (±0.4 kPa)
IBP
Measurement range -50mmHg~ 300mmHg (-6.7kPa~ 40.0kPa)
Measurement accuracy ±3mmHg(±0.4kPa)
Resolution 1mmHg (0.1kPa)
ETCO2
Measurement mode Sidestream and mainstream
Measurement range 0 mmHg~150 mmHg (0 kPa~20.0 kPa)
Measurement accuracy 0 mmHg~40 mmHg (0 kPa~5.3 kPa), the error is ±2 mmHg (±0.26 kPa)
41 mmHg~70 mmHg (5.5 kPa~9.3 kPa), the error is ±5%
71 mmHg~100 mmHg (9.4 kPa~13.3 kPa), the error is ±8%
101 mmHg~150 mmHg (13.4 kPa~20.0 kPa), the error is ±10%
Other specification
Built-in lithium battery 10.95 V / 2750 mAh
10.95 V / 5500 mAh (option)
Display: 13.3 inch TFT display
Standard configuration
ECG, Respiration, SpO2, PR, NIBP, Temperature, WIFI
Options
2-IBP, EtCO2, Nellcor SpO2, SunTech NIBP, 12-lead ECG, Work station, AI Module
If you want to know more uses of china spo2 monitor, please visit our website.